- Violations on record
- 61vs. 117.3 per 100 units
- Confirmed still open
- 3
We have no recorded transfer on file for this property, so the records below may include ones that predate this owner.
We don't yet have complaints and eviction filings for this area, so they are not counted here or in the score. A blank is not a clean record — it means we have nothing to show.
Derived from public records. Not tenant opinion.
Properties and ownership1 property
Ownership records
Public records indicate this owner is connected to 1 property totalling 52 units. Connections between entities are inferred from public filings and are shown with the evidence behind them.
| Property | Units | On record | Recorded |
|---|---|---|---|
| 2290 UNIVERSITY AVENUEBronx, NYSSL 2032120021 | 52 | 3 | — |
Sources: NYC HPD — Multiple Dwelling Registrations and Registration Contacts. Ownership information is presented as recorded and may be incomplete or out of date.
Company links are inferences from shared addresses, agents and name similarity — never a finding. Each one shows the evidence that produced it.
Tenant reviews (0)
Ordered by what other tenants found helpful (§3.6). Voting changes the order only — never a score.
No published reviews yet.
Every violation on record
The individual records behind the counts above, most recent first.
| Opened | Property | Severity | What was recorded | Status |
|---|---|---|---|---|
| 8 Sept 2026 | 2290 UNIVERSITY AVENUEBronx, NY | Moderate | §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMATION/REQUIRED-SIGNAGE.PAGE | Confirmed still open |
| 20 Mar 2026 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ITS ASSEMBLIES AT BULKHEAD DOOR AT 2nd PUBLIC HALL BULKHEAD FROM NORTH, 6th STORY, SECTION ''SOUTH'' | Closed 18 Jun 2026 |
| 20 Mar 2026 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT 2nd PUBLIC HALL BULKHEAD FROM NORTH, 6th STORY, SECTION ''SOUTH'' | Closed 11 Apr 2026 |
| 6 Mar 2026 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WINDOW AT 3RD STORY INTERMEDITE LANDING AT SOUTH WALL ,CREATING A GUILLOTINE EFFECT AT PUBLIC HALL STAIRS, 3rd STORY, SECTION AT SOUTH | Closed 29 May 2026 |
| 6 Mar 2026 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2005 ADM CODE PROVIDE WIRE TYPE MESH GLASS AT TOP PANE OF WINDOW, AT 6TH STORY INTERMEIDE LANDING AT SOUTH WALL AT SOUTH SECTION AT PUBLIC HALL STAIRS, 6th STORY, SECTION AT SOUTH | Closed 29 May 2026 |
| 6 Mar 2026 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CRACKED GLASS,AT WINDOW AT SOUTH WIALL AT 6TH STORY INTERMEDITE LANDING (SOUTH SECTION) AT PUBLIC HALL STAIRS, 6th STORY, SECTION AT SOUTH | Closed 29 May 2026 |
| 6 Mar 2026 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ROOF DOOR HITTING FRAME, AT 2nd PUBLIC HALL BULKHEAD FROM NORTH, SECTION AT SOUTH | Closed 19 Mar 2026 |
| 6 Mar 2026 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2005 ADM CODE PROVIDE ACCEPTABLE MECHANICAL HEAVY DUTY LOCK AND LATCH SET AT THE ROOF DOOR, ALLOWING RE-ENTRY, FROM ROOF TO PUBLIC HALL BULKHEAD (FROM ROOF TO PUBLIC HALL BULKHEAD NORTH SECTION) AT 1st PUBLIC HALL BULKHEAD FROM NORTH, SECTION AT NORTH | Closed 29 May 2026 |
| 9 Feb 2026 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING CONSISTING OF A DOOR SWEEP INSTALLED AT ROOF DOOR AT 2nd PUBLIC HALL BULKHEAD FROM NORTH, 6th STORY | Closed 5 Mar 2026 |
| 9 Feb 2026 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF HOUSEHOLD ITEMS AT 4TH STORY BALCONY AT 1ST FIRE ESCAPE FROM NORTH AT WEST EXTERIOR WALL | Closed 4 May 2026 |
| 4 Dec 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' | Closed 10 Dec 2024 |
| 4 Dec 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM | Closed 18 Feb 2025 |
| 4 Dec 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' | Closed 18 Feb 2025 |
| 7 Oct 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CRACKED BRICKS AND ERRODED MORTAR JOINTS AT PARAPET WALL BUILDING FRONT | Closed 15 Jan 2025 |
| 27 Sept 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT FIRE DOOR AT NORTH AT FRONT COURTYARD AT LEADING TO GARBAGE/ RECYCLING AREA | Closed 13 Oct 2024 |
| 26 Sept 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 67 M/D LAW POST A PRINTED SCALE FLOOR PLAN SHOWING MEANS OF EGRESS, AT STAIRS , 2nd STORY | Closed 20 Nov 2024 |
| 23 Sept 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Moderate | § 27-2022 ADM CODE POST A SIGN INDICATING HOURS OF COLLECTION AND METHOD OF COLLECTION OF WASTE MATERIAL WHERE DUMBWAITER SERVICE IS NOT PROVIDED. AT PUBLIC HALL, 2nd STORY | Closed 15 Jan 2025 |
| 23 Sept 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Moderate | § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 2nd STORY | Closed 15 Jan 2025 |
| 23 Sept 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Moderate | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. | Closed 15 Jan 2025 |
| 9 Sept 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 3C , 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTH'' | Closed 20 Sept 2024 |
| 9 Sept 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3C , 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTH'' | Closed 27 Nov 2024 |
| 9 Sept 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3C , 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTH'' | Closed 27 Nov 2024 |
| 9 Sept 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SINK WOOD CABINET IN THE KITCHEN LOCATED AT APT 3C , 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTH'' | Closed 27 Nov 2024 |
| 9 Sept 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 3C , 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTH'' | Closed 27 Nov 2024 |
| 9 Sept 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE WATER SUPPLY PIPE AT SINK IN THE KITCHEN LOCATED AT APT 3C , 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTH'' | Closed 27 Nov 2024 |
| 29 Aug 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOORS LOCKED AT BOILER ROOM | Closed 14 Nov 2024 |
| 29 Aug 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE KITCHEN LOCATED AT APT 1B, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST | Closed 20 Sept 2024 |
| 1 Apr 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF BICYCLES AT PUBLIC HALL, 1st STORY, SECTION ''NORTH'' | Closed 15 Jul 2024 |
| 1 Apr 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCES AT THE LOWER SASH WINDOW AT THE INTERMEDIATE LANDING AT PUBLIC HALL STAIRS, 6th STORY, SECTION ''NORTH'' | Closed 15 Jul 2024 |
| 1 Apr 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Moderate | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 6th STORY, SECTION ''NORTH'' | Closed 15 Jul 2024 |
| 1 Apr 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 6th STORY, SECTION ''NORTH'' | Closed 15 Jul 2024 |
| 1 Apr 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT THE CEILING AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 6th STORY, SECTION ''NORTH'' | Closed 15 Jul 2024 |
| 1 Apr 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Moderate | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL, EAST WALL, SOUTH WALL, WEST WALL, AND THE CEILING IN THE BATHROOM LOCATED AT APT 5B, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH | Closed 15 Jul 2024 |
| 1 Apr 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT THE NORTH WALL, EAST WALL, SOUTH WALL, WEST WALL, AND THE CEILING APPROXIMATELY 60 SQ.FT. IN THE BATHROOM LOCATED AT APT 5B, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH | Confirmed still open |
| 1 Apr 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Moderate | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE REGLAZE THE BATHTUB IN THE BATHROOM LOCATED AT APT 5B, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH | Closed 15 Jul 2024 |
| 1 Apr 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH | Closed 15 Jul 2024 |
| 1 Apr 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT THE SINK IN THE KITCHEN LOCATED AT APT 5B, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH | Closed 15 Jul 2024 |
| 1 Apr 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Moderate | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BASE CABINET DOORS IN THE KITCHEN LOCATED AT APT 5B, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH | Closed 15 Jul 2024 |
| 1 Apr 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ROTTED WOOD BASE CABINET AT SINK IN THE KITCHEN LOCATED AT APT 5B, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH | Closed 15 Jul 2024 |
| 1 Apr 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH | Closed 15 Jul 2024 |
| 1 Apr 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH | Closed 15 Jul 2024 |
| 1 Apr 2024 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH | Closed 15 Jul 2024 |
| 15 Feb 2023 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE THE 1ST MASONARY TREAD UP FROM BOTTOM NORTH SECTION AT PUBLIC HALL STAIRS, 2nd STORY | Closed 30 Mar 2023 |
| 9 Jan 2023 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Closed 29 Mar 2023 |
| 9 Jan 2023 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WOOD BASE CABINET UNDER SINK. IN THE KITCHEN LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Closed 29 Mar 2023 |
| 9 Jan 2023 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST AND NORTH WALL IN THE KITCHEN LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Closed 29 Mar 2023 |
| 9 Jan 2023 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE WATER SUPPLY PIPE UNDER KITCHEN SINK. IN THE KITCHEN LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Closed 29 Mar 2023 |
| 9 Jan 2023 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL TILE FLOOR, CUT HAZARD IN THE KITCHEN LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Closed 29 Mar 2023 |
| 9 Jan 2023 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Closed 29 Mar 2023 |
| 9 Jan 2023 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM | Closed 29 Mar 2023 |
| 6 Jan 2023 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE 4th ROOM FROM NORTH LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Closed 30 Jan 2023 |
| 4 Jan 2023 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOORS AT BOILER ROOM | Closed 20 Mar 2023 |
| 4 Jan 2023 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE 1st ROOM FROM EAST LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Closed 20 Mar 2023 |
| 1 Mar 2022 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE HEAVY DUTY LOCKSET AND IT'S ASSEMBLY AT BUILDING ENTRANCE DOOR , 1st STORY | Closed 25 May 2022 |
| 17 Feb 2022 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APROX 21 SQ FT, 12 SQ FT AT SOUTH WALL, 4 SQ FT AT CEILING, 5 SQ FT AT EAST WALL. IN THE BATHROOM LOCATED AT APT 4H, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST | Confirmed still open |
| 17 Feb 2022 | 2290 UNIVERSITY AVENUEBronx, NY | Moderate | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING IN THE BATHROOM LOCATED AT APT 4H, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST | Closed 3 May 2022 |
| 17 Feb 2022 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4H, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST | Closed 3 May 2022 |
| 17 Feb 2022 | 2290 UNIVERSITY AVENUEBronx, NY | Serious | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). IN THE ENTIRE APARTMENT LOCATED AT APT 4H, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST | Closed 3 May 2022 |
| 17 Feb 2022 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE ENTRANCE LOCATED AT APT 4H, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST | Closed 3 May 2022 |
| 7 Jan 2022 | 2290 UNIVERSITY AVENUEBronx, NY | Hazardous | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , 1st SECTION FROM WEST AT NORTH | Closed 20 Apr 2022 |