Getty Industries LLC
1 property · 50 units
Tenant score
No tenant reviews yet. The public record below is drawn from government sources and does not depend on reviews.
Public Records
Bottom 12%of this area owners with records
Fewer housing-code records than 12% of this area owners that have records on file — most owners have none, and are not ranked.
- Violations on record
- 106vs. 212.0 per 100 units
- Confirmed still open
- 42
We have no recorded transfer on file for this property, so the records below may include ones that predate this owner.
We don't yet have complaints and eviction filings for this area, so they are not counted here or in the score. A blank is not a clean record — it means we have nothing to show.
Derived from public records. Not tenant opinion.
Properties and ownership1 property
Ownership records
Public records indicate this owner is connected to 1 property totalling 50 units. Connections between entities are inferred from public filings and are shown with the evidence behind them.
| Property | Units | On record | Recorded |
|---|---|---|---|
| 5008 BROADWAYNew York, NYSSL 1022300005 | 50 | 42 | — |
Sources: NYC HPD — Multiple Dwelling Registrations and Registration Contacts. Ownership information is presented as recorded and may be incomplete or out of date.
Company links are inferences from shared addresses, agents and name similarity — never a finding. Each one shows the evidence that produced it.
Tenant reviews (0)
Ordered by what other tenants found helpful (§3.6). Voting changes the order only — never a score.
No published reviews yet.
Every violation on record
The individual records behind the counts above, most recent first.
| Opened | Property | Severity | What was recorded | Status |
|---|---|---|---|---|
| 18 Sept 2026 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1, WG TO REPLACE = 0, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 18 Sept 2026 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE 4th ROOM FROM EAST LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 18 Sept 2026 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS PANE AT LOWER WINDOW SASH IN THE 2nd ROOM FROM EAST LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 10 Sept 2026 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURE AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Confirmed still open |
| 10 Sept 2026 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0, WG TO REPLACE = 2, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Confirmed still open |
| 10 Sept 2026 | 5008 BROADWAYNew York, NY | Hazardous | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Confirmed still open |
| 10 Sept 2026 | 5008 BROADWAYNew York, NY | Serious | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Confirmed still open |
| 10 Sept 2026 | 5008 BROADWAYNew York, NY | Serious | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Confirmed still open |
| 10 Sept 2026 | 5008 BROADWAYNew York, NY | Serious | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN AT BATHTUB IN THE BATHROOM LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Confirmed still open |
| 10 Sept 2026 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE INOPERABLE HINGES AT DOOR IN THE ENTRANCE LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Confirmed still open |
| 22 Jun 2026 | 5008 BROADWAYNew York, NY | Moderate | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND NORTH WALL IN THE KITCHEN LOCATED AT APT 5D, 5th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Confirmed still open |
| 16 Apr 2026 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE 4th ROOM FROM EAST LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Closed 15 Jul 2026 |
| 16 Apr 2026 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Closed 15 Jul 2026 |
| 16 Apr 2026 | 5008 BROADWAYNew York, NY | Serious | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Closed 15 Jul 2026 |
| 5 Feb 2026 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed 5 May 2026 |
| 4 Dec 2025 | 5008 BROADWAYNew York, NY | Moderate | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE KITCHEN LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed 17 Mar 2026 |
| 4 Dec 2025 | 5008 BROADWAYNew York, NY | Moderate | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THE 10SQ FT OF MOLD ON THE CEILING IN THE KITCHEN LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed 5 Mar 2026 |
| 4 Dec 2025 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SILICONE CAULK AT TILES AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed 17 Mar 2026 |
| 4 Dec 2025 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN FINISH AT BATHTUB IN THE BATHROOM LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed 17 Mar 2026 |
| 4 Dec 2025 | 5008 BROADWAYNew York, NY | Moderate | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION SYSTEM AT CEILING IN THE BATHROOM LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed 17 Mar 2026 |
| 4 Dec 2025 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST WALL, THE WEST WALL,THE NORTH WALL AND THE CEILING IN THE BATHROOM LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed 17 Mar 2026 |
| 4 Dec 2025 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER SASH, SRING BALANCE AT 2ND WINDOW FROM WEST AT NORTH IN THE 3rd ROOM FROM EAST LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed 17 Mar 2026 |
| 4 Dec 2025 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL, SOUTH WALL AND CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed 17 Mar 2026 |
| 4 Dec 2025 | 5008 BROADWAYNew York, NY | Moderate | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH WALL AND THE EAST WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed 17 Mar 2026 |
| 4 Dec 2025 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DEFECTIVE SHUT OFF VALVE IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed 17 Mar 2026 |
| 4 Dec 2025 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed 17 Mar 2026 |
| 20 Oct 2025 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING IN THE ROOM LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 20 Oct 2025 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 20 Oct 2025 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, EAST WALL IN THE ROOM LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 20 Oct 2025 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING IN THE ROOM LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 14 Oct 2025 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 HMC: REFIT THE DOOR IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 14 Oct 2025 | 5008 BROADWAYNew York, NY | Moderate | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING , 6th STORY | Confirmed still open |
| 14 Oct 2025 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING , 6th STORY | Confirmed still open |
| 14 Oct 2025 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE FIRE DOOR AT PUBLIC HALL, 5th STORY | Closed 13 Nov 2025 |
| 14 Oct 2025 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT VESTIBULE DOOR AT PUBLIC HALL, 1st STORY | Confirmed still open |
| 8 Oct 2025 | 5008 BROADWAYNew York, NY | Moderate | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 8 Oct 2025 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) WEST WALL IN THE KITCHEN LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 8 Oct 2025 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 AND IS PRESUMED LEAD PAINT AS SET FORTH IN (28 RCNY §11-07(b)) AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE-USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(b)(2) 1st WINDOW FRAME FROM EAST AT SOUTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 8 Oct 2025 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) EAST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 8 Oct 2025 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 8 Oct 2025 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL LIGHT FIXTURE AT CEILING IN THE FOYER LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 8 Oct 2025 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE UPPER SASH FIRST WINDOW FROM EAST AT SOUTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 8 Oct 2025 | 5008 BROADWAYNew York, NY | Hazardous | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Closed 8 Jan 2026 |
| 8 Oct 2025 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 2, WG TO REPLACE = 0, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 8 Oct 2025 | 5008 BROADWAYNew York, NY | Serious | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 8 Oct 2025 | 5008 BROADWAYNew York, NY | Serious | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 8 Oct 2025 | 5008 BROADWAYNew York, NY | Serious | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 8 Oct 2025 | 5008 BROADWAYNew York, NY | Moderate | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE KITCHEN LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 8 Oct 2025 | 5008 BROADWAYNew York, NY | Serious | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 8 Oct 2025 | 5008 BROADWAYNew York, NY | Moderate | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 8 Oct 2025 | 5008 BROADWAYNew York, NY | Serious | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 8 Oct 2025 | 5008 BROADWAYNew York, NY | Moderate | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT SOUTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 8 Oct 2025 | 5008 BROADWAYNew York, NY | Moderate | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 8 Oct 2025 | 5008 BROADWAYNew York, NY | Serious | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Confirmed still open |
| 7 Oct 2025 | 5008 BROADWAYNew York, NY | Serious | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES LARGE BICYCLE AT 3RD STORY OF 2ND FIRE ESCAPE FROM NORTH AT EAST | Confirmed still open |
| 25 Aug 2025 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WINDOW GUARD PREVENTING EGRESS TO FIRE ESCAPE AT THE 1ST WINDOW FROM EAST AT SOUTH IN THE 4th ROOM FROM EAST LOCATED AT APT 2H, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed 26 Mar 2026 |
| 25 Aug 2025 | 5008 BROADWAYNew York, NY | Moderate | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQFT AT CEILING AND EAST WALL IN THE 4th ROOM FROM EAST LOCATED AT APT 2H, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed 6 Oct 2025 |
| 22 Aug 2025 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF REFRIGERATOR WITH DOORS INTACT AT PUBLIC HALL, 2nd STORY | Closed 6 Oct 2025 |
| 22 Aug 2025 | 5008 BROADWAYNew York, NY | Serious | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2H, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed 26 Mar 2026 |
| 22 Aug 2025 | 5008 BROADWAYNew York, NY | Serious | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2H, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed 26 Mar 2026 |
| 22 Aug 2025 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST AND WEST WALLS IN THE BATHROOM LOCATED AT APT 2H, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed 6 Oct 2025 |
| 22 Aug 2025 | 5008 BROADWAYNew York, NY | Moderate | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT WEST WALL IN THE BATHROOM LOCATED AT APT 2H, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed 6 Oct 2025 |
| 21 Jul 2025 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT FIRE DOOR AT PUBLIC HALL, 5th STORY, SECTION AT EAST | Closed 4 Nov 2025 |
| 14 Jul 2025 | 5008 BROADWAYNew York, NY | Moderate | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT WEST BULKHEAD CEILING AT PUBLIC HALL , 6th STORY | Confirmed still open |
| 14 Jul 2025 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT WEST BULKHEAD CEILING AT PUBLIC HALL , 6th STORY | Confirmed still open |
| 26 Sept 2024 | 5008 BROADWAYNew York, NY | Hazardous | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2H, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST | Closed 2 Jan 2025 |
| 26 Sept 2024 | 5008 BROADWAYNew York, NY | Moderate | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT EAST WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 2H, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST | Closed 23 Jan 2025 |
| 26 Sept 2024 | 5008 BROADWAYNew York, NY | Serious | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 2H, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST | Closed 23 Jan 2025 |
| 26 Sept 2024 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM EAST LOCATED AT APT 2H, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST | Closed 23 Jan 2025 |
| 26 Sept 2024 | 5008 BROADWAYNew York, NY | Serious | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST AND WEST WALL IN THE BATHROOM LOCATED AT APT 2H, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST | Closed 23 Jan 2025 |
| 26 Sept 2024 | 5008 BROADWAYNew York, NY | Moderate | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT EAST AND WEST WALL IN THE BATHROOM LOCATED AT APT 2H, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST | Closed 23 Jan 2025 |
| 26 Sept 2024 | 5008 BROADWAYNew York, NY | Serious | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN IN THE BATHROOM LOCATED AT APT 2H, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST | Closed 23 Jan 2025 |
| 26 Sept 2024 | 5008 BROADWAYNew York, NY | Moderate | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FTS AT SOUTH WALL AND WEST WALL. IN THE BATHROOM LOCATED AT APT 2H, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST | Closed 30 Jan 2025 |
| 26 Sept 2024 | 5008 BROADWAYNew York, NY | Hazardous | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2H, 2nd STORY, 3rd APARTMENT FROM SOUTH AT WEST | Closed 2 Jan 2025 |
| 15 Apr 2024 | 5008 BROADWAYNew York, NY | Hazardous | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF RODENTS RATS AT NORTH COURT YARD | Closed 7 Aug 2025 |
| 15 Apr 2024 | 5008 BROADWAYNew York, NY | Serious | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT APT3C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Closed 22 Jul 2024 |
| 15 Apr 2024 | 5008 BROADWAYNew York, NY | Serious | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT APT3C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Closed 22 Jul 2024 |
| 15 Apr 2024 | 5008 BROADWAYNew York, NY | Hazardous | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT APT3C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Closed 22 Jul 2024 |
| 15 Apr 2024 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PROCLEAIN ENAMEL GLAZE AT BATHTUB IN THE BATHROOM LOCATED AT APT APT3C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Closed 26 Mar 2026 |
| 2 Apr 2024 | 5008 BROADWAYNew York, NY | Serious | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). 2ND UNIT MISSING 15 FT WITHIN SLEEPING AREA IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Closed 13 Jul 2025 |
| 2 Apr 2024 | 5008 BROADWAYNew York, NY | Serious | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR 2ND UNIT MISSING 15 FT WITHIN SLEEPING AREA IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Closed 13 Jul 2025 |
| 2 Apr 2024 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, SOUTH AND EAST WALLS IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Closed 13 Jul 2025 |
| 24 Nov 2023 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT FIRE DOOR AT PUBLIC HALL, 2nd STORY | Closed 20 Feb 2024 |
| 24 Nov 2023 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT FIRE DOOR AT PUBLIC HALL, 3rd STORY | Closed 20 Mar 2024 |
| 24 Nov 2023 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT FIRE DOOR AT PUBLIC HALL, 4th STORY | Closed 25 Dec 2023 |
| 24 Nov 2023 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT FIRE DOOR AT PUBLIC HALL, 5th STORY | Confirmed still open |
| 24 Nov 2023 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT PUBLIC HALL, 6th STORY | Closed 13 Jul 2025 |
| 24 Nov 2023 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING HASP AND EYE CAPABLE OF BEING PADLOCK AT GATE AT EAST YARD LEADING TO FIRE ESCAPE | Closed 14 Jul 2025 |
| 5 Jun 2023 | 5008 BROADWAYNew York, NY | Moderate | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND WALLS AT WEST BULKHEAD, AT PUBLIC HALL, 6th STORY | Confirmed still open |
| 5 Jun 2023 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL CEILING AND WALLS WEST BULKHEAD, AT PUBLIC HALL, 6th STORY | Closed 22 Nov 2023 |
| 5 Jun 2023 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK AT DOOR LEADING TO FIRE ESCAPE, LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed 22 Nov 2023 |
| 8 May 2023 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE MORTAR JOINT AT NORTHWEST CORNER BUILDING AT PARAPET WALL | Closed 6 Oct 2025 |
| 1 May 2023 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING WOOD WEDGE AT FIRE DOOR AT PUBLIC HALL, 6th STORY | Closed 22 Nov 2023 |
| 25 Apr 2023 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE UPPER WINDOW SASH AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Closed 13 Oct 2025 |
| 25 Apr 2023 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEDING 130 DEGREES AT FIXTURES IN THE BATHROOM AND KITCHEN IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Closed 26 Jul 2023 |
| 24 Apr 2023 | 5008 BROADWAYNew York, NY | Serious | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF STROLLER UNDER SOUTH STAIRCASE. AT PUBLIC HALL STAIRS, 1st STORY | Closed 22 Nov 2023 |
| 13 Apr 2023 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE EGREES DOOR SEALED SHUT AT SOUTH IN THE KITCHEN LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''South'' | Closed 22 Nov 2023 |
| 11 Apr 2023 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE PUBLIC HALL DOOR AT PUBLIC HALL, 2nd STORY | Closed 13 Jul 2025 |
| 11 Apr 2023 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE PUBLIC HALL DOOR AT PUBLIC HALL, 6th STORY | Closed 13 Jul 2025 |
| 21 Mar 2023 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR AT VESTIBULE ENTRANCE , 1st STORY | Closed 1 May 2023 |
| 21 Mar 2023 | 5008 BROADWAYNew York, NY | Serious | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS AT STACK AT BUILDING REAR AT FIRE ESCAPE | Closed 1 Jun 2023 |
| 23 Feb 2023 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ROOF DOOR | Closed 2 Jun 2023 |
| 23 Feb 2023 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE IN THE ENTRANCE LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Closed 22 Nov 2023 |
| 23 Feb 2023 | 5008 BROADWAYNew York, NY | Serious | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4G, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST | Closed 26 Jun 2023 |
| 23 Feb 2023 | 5008 BROADWAYNew York, NY | Serious | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4G, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST | Closed 26 Jun 2023 |
| 23 Feb 2023 | 5008 BROADWAYNew York, NY | Hazardous | § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST | Closed 28 Nov 2023 |