66 Pearl LLC
1 property · 42 units
Tenant score
No tenant reviews yet. The public record below is drawn from government sources and does not depend on reviews.
Public Records
Bottom 24%of this area owners with records
Fewer housing-code records than 24% of this area owners that have records on file — most owners have none, and are not ranked.
- Violations on record
- 53vs. 126.2 per 100 units
- Confirmed still open
- 16
We have no recorded transfer on file for this property, so the records below may include ones that predate this owner.
We don't yet have complaints and eviction filings for this area, so they are not counted here or in the score. A blank is not a clean record — it means we have nothing to show.
Derived from public records. Not tenant opinion.
Properties and ownership1 property
Ownership records
Public records indicate this owner is connected to 1 property totalling 42 units. Connections between entities are inferred from public filings and are shown with the evidence behind them.
| Property | Units | On record | Recorded |
|---|---|---|---|
| 1 COENTIES SLIPNew York, NYSSL 1000077501 | 42 | 16 | — |
Sources: NYC HPD — Multiple Dwelling Registrations and Registration Contacts. Ownership information is presented as recorded and may be incomplete or out of date.
Company links are inferences from shared addresses, agents and name similarity — never a finding. Each one shows the evidence that produced it.
Tenant reviews (0)
Ordered by what other tenants found helpful (§3.6). Voting changes the order only — never a score.
No published reviews yet.
Every violation on record
The individual records behind the counts above, most recent first.
| Opened | Property | Severity | What was recorded | Status |
|---|---|---|---|---|
| 10 Feb 2026 | 1 COENTIES SLIPNew York, NY | Serious | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE RADIATOR AT EAST WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 204, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Closed 26 May 2026 |
| 28 Jan 2026 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE 1st ENTIRE APARTMENT FROM EAST LOCATED AT APT 204, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Closed 13 Apr 2026 |
| 20 Jan 2026 | 1 COENTIES SLIPNew York, NY | Serious | § 27-2005 ADM CODE PROVIDE SECURITY IN THE EVENT OF A POWER OUTAGE WITH A HEAVY DUTY LOCK LATCH SET AT VESTIBULE DOOR AT PUBLIC HALL, 1st STORY | Confirmed still open |
| 20 Jan 2026 | 1 COENTIES SLIPNew York, NY | Serious | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING AN UNACCEPTABLE ELECTROMEGNETIC LOCKING DEVICE INSTALLED AT VESTIBULE DOOR AT PUBLIC HALL, 1st STORY | Confirmed still open |
| 20 Jan 2026 | 1 COENTIES SLIPNew York, NY | Moderate | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AT PUBLIC HALL, 2nd STORY | Closed 26 May 2026 |
| 20 Jan 2026 | 1 COENTIES SLIPNew York, NY | Serious | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 2nd STORY | Closed 13 Apr 2026 |
| 26 Oct 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005 ADM CODE PROVIDE LOCK AND ASSEMBLY AT VESTIBULE DOOR TO PUBLIC HALL , 1st STORY | Confirmed still open |
| 26 Oct 2023 | 1 COENTIES SLIPNew York, NY | Moderate | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 502 UPPER LEVEL, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Confirmed still open |
| 26 Oct 2023 | 1 COENTIES SLIPNew York, NY | Serious | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE BATHROOM LOCATED AT APT 502 UPPER LEVEL, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Closed 26 Jan 2024 |
| 26 Oct 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING ELECTROMAGNETIC LOCKING DEVICE REQUIRING PUSH BUTTON TO EXIT AT VESTIBULE DOOR , 1st STORY | Confirmed still open |
| 26 Oct 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE FRAMES AT VESTIBULE DOOR TO PUBLIC HALL , 1st STORY | Confirmed still open |
| 26 Oct 2023 | 1 COENTIES SLIPNew York, NY | Serious | § 27-2005 HMC: REFIT LOWER SASH AT WEST WINDOW IN THE 1st ROOM FROM NORTH LOCATED AT APT 502 UPPER LEVEL, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Closed 26 Jan 2024 |
| 26 Oct 2023 | 1 COENTIES SLIPNew York, NY | Moderate | § 27-2065 ADM CODE PROVIDE VENTILATION FOR WATER CLOSET COMPARTMENT AND/OR BATHROOM AND FILE APPLICATION FOR APPROVAL BEFORE DOING WORK IN THE BATHROOM LOCATED AT APT 502 LOWER LEVEL, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Confirmed still open |
| 26 Oct 2023 | 1 COENTIES SLIPNew York, NY | Moderate | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL IN THE BATHROOM LOCATED AT APT 502 LOWER LEVEL, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Closed 26 Jan 2024 |
| 26 Oct 2023 | 1 COENTIES SLIPNew York, NY | Moderate | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST WALL IN THE BATHROOM LOCATED AT APT 502 LOWER LEVEL, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Confirmed still open |
| 30 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT BUILDING ENTRANCE DOOR , 1st STORY | Closed 20 Feb 2024 |
| 30 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005 ADM CODE PROVIDE HEAVY DUTY LOCK, AT BUILDING ENTRANCE DOOR TO PUBLIC HALL , 1st STORY | Confirmed still open |
| 30 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF ELECTROMAGNETIC LOCK AT VESTIBULE DOOR TO PUBLIC HALL , 1st STORY | Confirmed still open |
| 30 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT VESTIBULE DOOR TO PUBLIC HALL , 1st STORY | Closed 21 Jul 2023 |
| 30 May 2023 | 1 COENTIES SLIPNew York, NY | Moderate | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 6th STORY, SECTION ''SOUTH'', AT SOUTH | Closed 13 Nov 2023 |
| 30 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 6th STORY, SECTION ''SOUTH'', AT SOUTH | Confirmed still open |
| 30 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LEADING TO BASEMENT AT PUBLIC HALL, 1st STORY | Closed 21 Jul 2023 |
| 8 May 2023 | 1 COENTIES SLIPNew York, NY | Serious | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF BUILDING MATERIALS AND LADDER AT PUBLIC HALL STAIRS, 6th STORY | Confirmed still open |
| 8 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE FIRE DOOR LEADING TO SOUTH WING AT PUBLIC HALL, 5th STORY | Closed 27 May 2023 |
| 8 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING TAPE OBSTRUCTING FIRE DOOR LEADING TO SOUTH WING AT PUBLIC HALL, 5th STORY | Closed 27 May 2023 |
| 8 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HOPPER DOOR AT PUBLIC HALL, 5th STORY | Closed 21 Jul 2023 |
| 8 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR LEADING TO STAIRCASE AT PUBLIC HALL, 5th STORY | Closed 27 May 2023 |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HOPPER DOOR AT PUBLIC HALL, 2nd STORY | Closed 20 Feb 2024 |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE COMPACTOR ROOM DOOR AT PUBLIC HALL, 2nd STORY | Closed 27 May 2023 |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR LEADING TO PUBLIC STAIRWELL AT PUBLIC HALL, 2nd STORY | Closed 1 Jul 2024 |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING WIRE OBSTRUCTING DOOR LEADING TO PUBLIC STAIRWELL AT PUBLIC HALL, 2nd STORY | Closed 27 May 2023 |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE FIRE DOOR LEADING TO SOUTH WING AT PUBLIC HALL, 2nd STORY | Closed 27 May 2023 |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING CARD BOARD OBSTRUCTING FIRE DOOR LEADING TO SOUTH WING AT PUBLIC HALL, 2nd STORY | Closed 27 May 2023 |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING CARD BOARD OBSTRUCTING FIRE DOOR LEADING TO SOUTH WING AT PUBLIC HALL, 3rd STORY | Closed 27 May 2023 |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE FIRE DOOR LEADING TO SOUTH WING AT PUBLIC HALL, 3rd STORY | Closed 27 May 2023 |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES TO HOPPER DOOR AT PUBLIC HALL, 3rd STORY | Closed 20 Feb 2024 |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR LEADING TO PUBLIC STAIRCASE AT PUBLIC HALL, 3rd STORY | Closed 27 May 2023 |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE FIRE DOOR LEADING TO SOUTH WING AT PUBLIC HALL, 4th STORY | Closed 27 May 2023 |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING TAPE OBSTRUCTING FIRE DOOR LEADING TO SOUTH WING AT PUBLIC HALL, 4th STORY | Closed 27 May 2023 |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES TO COMPACTOR DOOR AT PUBLIC HALL, 4th STORY | Closed 20 Feb 2024 |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HOPPER DOOR AT PUBLIC HALL, 4th STORY | Closed 27 May 2023 |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Serious | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FITRE RETARDANT MATERIAL AT THE CEILING IN EAST WING AT PUBLIC HALL, 6th STORY | Confirmed still open |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Serious | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF LARGE HOUSEHOLD ARTICLES AND BUILDING MATERIALS AT PUBLIC HALL, 6th STORY | Confirmed still open |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING CARD BOARD OBSTRUCTING FIRE DOOR AT PUBLIC HALL, 6th STORY | Closed 27 May 2023 |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE FIRE DOOR LEADING TO SOUTH WING AT PUBLIC HALL, 6th STORY | Closed 27 May 2023 |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR TO PUBLIC HALL STAIRWELL AT PUBLIC HALL, 6th STORY | Closed 27 May 2023 |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HOPPER DOORS AT PUBLIC HALL, 6th STORY | Closed 20 Feb 2024 |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE COMPACTOR ROOM DOOR AT PUBLIC HALL, 6th STORY | Closed 27 May 2023 |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Serious | § 27-2005 ADM CODE PROVIDE LIDS TO GARBAGE CANS AT BASEMENT | Confirmed still open |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Serious | § 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AND ARRANGE FOR COLLECTION AND DISPOSAL OF SUCH MATERIAL. | Confirmed still open |
| 3 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR LEADING TO PUBLIC STAIRWELL AT PUBLIC HALL, 1st STORY | Closed 20 Feb 2024 |
| 2 May 2023 | 1 COENTIES SLIPNew York, NY | Hazardous | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT BUILDING ENTRANCE | Closed 20 Feb 2024 |
| 15 Feb 2022 | 1 COENTIES SLIPNew York, NY | Moderate | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Closed 18 Feb 2022 |